NIBE SP 300 boiler
NIBE SP 300 boiler
• The NIBE SP comprises two indirectly heated boilers with a double jacket: SP 110 and SP 300. Heat transfer takes place via the double jacket and not via a heating coil. This makes NIBE SP boilers particularly suitable for use on board ships. In addition, the NIBE SP 300 type can be easily connected to a NIBE ELK 213 external electrical element with a capacity of 7-13 kW. The copper-lined boiler vessel of the NIBE SP is seamlessly insulated with polyurethane, which minimizes heat loss. (Label C) The maximum water temperature is 95°C. The water heaters can be installed both horizontally and vertically.
OMH 1: duct heater round Aluzinc OMH-G (basic)
OMH 1: duct heater round Aluzinc OMH-G (basic)
• Aluzinc housing with rubber seals suitable for clean air electrical heating, with temperature protection autoreset 50°C and manual reset 100 °C
• Available from stock Ø100-400mm, optional with control thermostat.OMH 2: duct heater galvanized OMH-G + control thermostat
OMH 2: duct heater galvanized OMH-G + control thermostat
• Alu-zinc housing Ø100/125/160/200/250/315/400mm, type OMH-G with built in safety thermotats 50°C autoreset and 100°C manual reset
• 3x400V models optionally with limit thermostat and control thermostat 0-40°C/0-90°C main current
• With rubber seals, IP 44, optionally with relay, flow control
• Applications: duct heating clean airOMH 3: duct heater round Aluzinc with built-in control: OMH-GNI, GNIS, GNV, GNV.PTC
OMH 3: duct heater round Aluzinc with built-in control: OMH-GNI, GNIS, GNV, GNV.PTC
• Alu-zinc casing with rubber seals and built in control(thyristor)
– 0-30 °C, external : DUCT HEATERS OMH-GNI
–0-10 Vdc : DUCT HEATERS OMH-GNIS
– 0-30 °C internal : DUCT HEATERS OMH-GNV
– 0-30 °C +flow control : DUCT HEATERS OMH-GNV.PTCOMH 4: duct heater, re-heater type galvanized OMH-KB
OMH 4: duct heater, re-heater type galvanized OMH-KB
• Housing galvanized Ø100/125/160/200/250/315/400 mm, type OMH-KB, with rubber seals
• Standard provided with maximum temperature protection 60 and 90°C(adjustment 0-90°C)
• Power supply various standard models or on specification 0,3-15kW, 230V 1F – 690V 3F
• IP 44 classification, heating elements 230V en 400V available
• Optionally with relay, flow control
• Applications: duct heating, HVACOMH 5: duct heater Stainless steel OMH
OMH 5: duct heater Stainless steel OMH
• Execution in Ø100/125/160/200/250/315/400mm, Length 375mm or made on specification
• Housing AISI 304/316L suitable for Spiro system with rubber seals, overheat protection 50°C auto reset en 100°C manual reset
• IP 44 classification
• Optional with contol thermostat, thyrister control, flowcontrol etc.
• Applications: duct heating, shipping, food etc.OMH 6: duct heater stainless steel FA / JACOB IP66
OMH 6: duct heater stainless steel FA / JACOB IP66
• Stainless steel housing 304/316 Ø100-650mm, compatible with FA- JKF tube systems, Jacob tube systems and KMH tube systems
• Capacity, power supply and control according to desired specifications
• optional: IP65, with main switch, control lights, relays and tension rings, etc.
• Application: air treatment, FA tube systems, etc.OMH 8: duct heater AISI with fan, IP65
OMH 8: duct heater AISI with fan, IP65
• Stainless steel housing, Ø210x300mm in 230V or 3x400V with ventilator fan
• 1500W-230V element: flat-oval 316L stainless steel, temperature control, flange o300x300mm
• Optional: other dimensions, capacity and power supply
• Execution normal with dan IP44 classification, with fan IP54 article 114469 or fan IP68 artikel 114467
• Application: drying process, air dryingOMH 9: duct heater stainless steel JACOB tube
OMH 9: duct heater stainless steel JACOB tube
• AISI 304 or 316L material, size Ø100- ± 630mm optional with suitable quick connect clamps and gaskets
• Capacity, power supply and control 0-10Vdc according to desired specifications, optional with flow control
• Application: air treatment, channel heating clean air with thyristor control
• Model: 6kW-3x400V, Ø250x500mmOMH 10, duct heater type OMH-LB, 230V
OMH 10, duct heater type OMH-LB, 230V
• Suitable for residential construction "ZERO ON THE METER" projects, for heating various rooms if the heat supply is not sufficient. • Housing 125/160/200x375mm with stainless steel elements with low loads, including overheating protection (excl. regulation), 230V • Application: residential building “ZERO ON THE METER”, BENG etc.
OMH 12: duct heater, air heater round galvanized OMH-GNV flowcontrol
OMH 12: duct heater, air heater round galvanized OMH-GNV flowcontrol
• Alu-zinc casing with rubber seals and built in control(thyristor)
– 0-30 °C +flow control : DUCT HEATERS OMH-GNV.PTC
OMH 13: duct heater round ISO 15138
OMH 13: duct heater round ISO 15138
• Housing galvanized steel or 316 stainless steel, Ø125- ± Ø650 mm, with removable element plate
• Capacity, power supply and surface load according to Norsok specifications, ISO 15138 with appropriate surface temperature heating elements
• Optional: in stages with fuses, circuit breaker, relay, safety mechanism and airflow monitoring, etc.